VARD00NOR Site Information Form (site log v2.0)
International GNSS Service
See Instructions at:
https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt
0. Form
Prepared by (full name) : [email protected]
Date Prepared : 2024-10-18
Report Type : UPDATE
If Update:
Previous Site Log : vard00nor_20181203.log
Modified/Added Sections : 11
1. Site Identification of the GNSS Monument
Site Name : Vardoe
Nine Character ID : VARD00NOR
Monument Inscription : STATENS KARTVERK
IERS DOMES Number : 10322M002
CDP Number : (A4)
Monument Description : (PILLAR/BRASS PLATE/STEEL MAST/etc)
Height of the Monument : (m)
Monument Foundation : (STEEL RODS, CONCRETE BLOCK, ROOF, etc)
Foundation Depth : (m)
Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc)
Date Installed : 1995-07-17
Geologic Characteristic : BEDROCK
Bedrock Type : METAMORPHIC
Bedrock Condition : (FRESH/JOINTED/WEATHERED)
Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
Fault zones nearby : (YES/NO/Name of the zone)
Distance/activity : (multiple lines)
Additional Information : Sedimentary bedrock.
:
: VARD
: Date removed: 2000-04-17T12:00Z
: Site superseded by VARS
:
2. Site Location Information
City or Town : Vardoe
State or Province : Finnmark
Country or Region : NOR
Tectonic Plate : EURASIAN
Approximate Position (ITRF)
X coordinate (m) : 1844607.623
Y coordinate (m) : 1109719.107
Z coordinate (m) : 5983936.007
Latitude (N is +) : +702010.93
Longitude (E is +) : +0310152.28
Elevation (m,ellips.) : 174.8
Additional Information : Local name is : DOMEN
3. GNSS Receiver Information
3.1 Receiver Type : TRIMBLE 4000SSI
Satellite System : GPS
Serial Number : 3511A10119
Firmware Version : 7.03
Elevation Cutoff Setting : 10 deg
Date Installed : 1995-07-17
Date Removed : 1998-06-16T18:00Z
Temperature Stabiliz. : (deg C) +/- (deg C)
Additional Information : (multiple lines)
3.2 Receiver Type : TRIMBLE 4000SSI
Satellite System : GPS
Serial Number : 3511A10119
Firmware Version : 7.28
Elevation Cutoff Setting : 10 deg
Date Installed : 1998-06-16T19:25Z
Date Removed : 2000-04-17T12:00Z
Temperature Stabiliz. : (deg C) +/- (deg C)
Additional Information : (multiple lines)
3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions)
Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
Serial Number : (A20, but note the first A5 is used in SINEX)
Firmware Version : (A11)
Elevation Cutoff Setting : (deg)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Temperature Stabiliz. : (none or tolerance in degrees C)
Additional Information : (multiple lines)
4. GNSS Antenna Information
4.1 Antenna Type : TRM23903.00 NONE
Serial Number : Unknown
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 5.0330
Marker->ARP North Ecc(m) : 0.0140
Marker->ARP East Ecc(m) : 0.0280
Alignment from True N : 0 deg
Antenna Radome Type : NONE
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : (m)
Date Installed : 1995-07-17
Date Removed : 1997-10-16T10:40Z
Additional Information : The antenna type TR GEOD L1/L2 GP is not
: the right type
: 45 degree angel roof made of glassfiber
4.2 Antenna Type : TRM29659.00 DOME
Serial Number : 0220098649
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 5.0330
Marker->ARP North Ecc(m) : 0.0140
Marker->ARP East Ecc(m) : 0.0280
Alignment from True N : 0 deg
Antenna Radome Type : DOME
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : (m)
Date Installed : 1997-10-16T11:13Z
Date Removed : 1998-06-16T18:00Z
Additional Information : Degree Offset from North : 180 ?
: Antenna contact pointed towards South
: 45 degree angel roof made of glassfiber
4.3 Antenna Type : TRM29659.00 SCIS
Serial Number : 0220098649
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 5.5120
Marker->ARP North Ecc(m) : 0.0060
Marker->ARP East Ecc(m) : 0.0170
Alignment from True N : 0 deg
Antenna Radome Type : SCIS
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : (m)
Date Installed : 1998-06-16T19:25Z
Date Removed : 2009-05-05T11:05Z
Additional Information : Degree Offset from North : 0?
: Antenna contact points towards North
: SCIS Installed 20-DEC-1999
4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions)
Serial Number : (A*, but note the first A5 is used in SINEX)
Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.)
Marker->ARP Up Ecc. (m) : (F8.4)
Marker->ARP North Ecc(m) : (F8.4)
Marker->ARP East Ecc(m) : (F8.4)
Alignment from True N : (deg; + is clockwise/east)
Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions)
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : (m)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
5. Surveyed Local Ties
5.1 Tied Marker Name : ARP of TRIMBLE permanent L1/L2
Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
Tied Marker CDP Number : (A4)
Tied Marker DOMES Number : (A9)
Differential Components from GNSS Marker to the tied monument (ITRS)
dx (m) : 1.427 m
dy (m) : 0.891 m
dz (m) : 4.744 m
Accuracy (mm) : 1 mm
Survey method : UNKNOWN
Date Measured : 1995-07-17
Additional Information : Differential coordinates from the GPS
: monument (Marker with Domes No.) to the ARP.
: The components are parallel to the XYZ-axes
: of the global geocentric reference system
: ITRF (WGS-84). Differential Components from
: GPS Mark to Site Reference (ITRS)
: (ARP minus top bolt)
5.2 Tied Marker Name : ARP of TRM29659.00
Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
Tied Marker CDP Number : (A4)
Tied Marker DOMES Number : (A9)
Differential Components from GNSS Marker to the tied monument (ITRS)
dx (m) : 1.427 m
dy (m) : 0.891 m
dz (m) : 4.744 m
Accuracy (mm) : 1 mm
Survey method : UNKNOWN
Date Measured : 1995-07-17
Additional Information : Differential coordinates from the GPS
: monument (Marker with Domes No.) to the ARP.
: The components are parallel to the XYZ-axes
: of the global geocentric reference system
: ITRF (WGS-84). Differential Components from
: GPS Mark to Site Reference (ITRS)
: (ARP minus top bolt)
5.3 Tied Marker Name : ARP of TRM29659.00
Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
Tied Marker CDP Number : (A4)
Tied Marker DOMES Number : (A9)
Differential Components from GNSS Marker to the tied monument (ITRS)
dx (m) : 1.576 m
dy (m) : 0.967 m
dz (m) : 5.192 m
Accuracy (mm) : 2 mm
Survey method : UNKNOWN
Date Measured : 1998-06-16
Additional Information : Differential coordinates from the GPS
: monument (Marker with Domes No.) to the ARP.
: The components are parallel to the XYZ-axes
: of the global geocentric reference system
: ITRF (WGS-84). Differential Components from
: GPS Mark to Site Reference (ITRS)
: (ARP minus top bolt)
5.x Tied Marker Name :
Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
Tied Marker CDP Number : (A4)
Tied Marker DOMES Number : (A9)
Differential Components from GNSS Marker to the tied monument (ITRS)
dx (m) : (m)
dy (m) : (m)
dz (m) : (m)
Accuracy (mm) : (mm)
Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
Date Measured : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
6. Frequency Standard
6.1 Standard Type : INTERNAL
Input Frequency : (if external)
Effective Dates : 1995-07-17/CCYY-MM-DD
Notes : (multiple lines)
6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
Input Frequency : (if external)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
7. Collocation Information
7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
Status : (PERMANENT/MOBILE)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8. Meteorological Instrumentation
8.1.x Humidity Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy (% rel h) : (% rel h)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.2.x Pressure Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (hPa)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.3.x Temp. Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (deg C)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.4.x Water Vapor Radiometer :
Manufacturer :
Serial Number :
Distance to Antenna : (m)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.5.x Other Instrumentation : (multiple lines)
9. Local Ongoing Conditions Possibly Affecting Computed Position
9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc)
Observed Degradations : (SN RATIO/DATA GAPS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.3.x Signal Obstructions : (TREES/BUILDINGS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
10. Local Episodic Effects Possibly Affecting Data Quality
10.x Date : (CCYY-MM-DD/CCYY-MM-DD)
Event : (TREE CLEARING/CONSTRUCTION/etc)
11. On-Site, Point of Contact Agency Information
Agency : Norwegian Mapping Authority
: Geodetic Institute
Preferred Abbreviation : NMA
Mailing Address : Kartverksveien 21 / P.O.Box 600 Sentrum
: N-3507 Honefoss
: Norway
Primary Contact
Contact Name : SATREF Control Centre
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail : [email protected]
Secondary Contact
Contact Name : Dr. Aasmund Steen Skjaeveland
Telephone (primary) : +47 32 11 84 52
Telephone (secondary) :
Fax : +47 32 11 81 01
E-mail : [email protected]
Additional Information : (multiple lines)
12. Responsible Agency (if different from 11.)
Agency : (multiple lines)
Preferred Abbreviation : (A10)
Mailing Address : (multiple lines)
Primary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Secondary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Additional Information : (multiple lines)
13. More Information
Primary Data Center : BKG
Secondary Data Center :
URL for More Information :
Hardcopy on File
Site Map : (Y or URL)
Site Diagram : (Y or URL)
Horizon Mask : (Y or URL)
Monument Description : (Y or URL)
Site Pictures : (Y or URL)
Additional Information : (multiple lines)
Antenna Graphics with Dimensions
TRM29659.00
Trimble L1/L2 Dorne Margolin element with chokerings
Model 29659.00
+-------+
/ + \ <-- 0.1280 L2
| + | <-- 0.1100 L1
+--------------------------------------------------+ <-- 0.1020 TCR
| |
| |
| |
| |
+-+--------------------------------------------------+-+ <-- 0.0380
+-------------------+-------------+--------------------+ <-- 0.0350 BCR
| |
| |
+------x------+ <-- 0.0 BPA=ARP
<-- 0.3810 -->
ARP: Antenna Reference Point
L1 : L1 Phase Center L2 : L2 Phase Center